- Stock: In Stock
- Model: MS6818 Mastech
MS6818 Mastech Digital Advanced Wire
Tracker
The MASTECH MS6818 Underground Wire Cable Metal Pipe Locator
Detector Tester consists of a signal transmitter and a receiver, widely used in
the construction and maintenance of communication cables, power cables, metal
pipes, and much more. Current and voltage conducting cables, electrical circuits,
conduits, water and heating pipelines, fuses, switches can all be located.
Short circuits and interruptions of assorted lines and cables can be detected.
Even better, the detection is possible not only underground but also in walls
and concrete.
Technical Parameters of Transmitter
Power supply: 1*9V 6F22 Battery
Product size:
190mm*89mm*42.5mm/7.48"*3.5"*1.67"
Product weight: 420g/0.92Ib
Safety rating: CE (EMC+LVD) ETL CAT.III 300V RoHS
Technical Parameter of Receiver
Power supply: 1*9V 6F22 Battery
Product size:
241.5mm*78mm*38.5mm/9.5"*3"*1.5"
Product weight: 350g/0.77Ib
Safety rating: CE (EMC+LVD) ETL CAT.III 300V RoHS
Find the Beaks or Shorts in Cable in the wall or Earth
Track Cables in the wall or Earth
Find the Fuse and Safeguard
Find the Beaks or Shorts in Conduit under the Floor
Track a Metal Conduit in the Project of ware or hot
Sensitivity of Receiver can be selected
Auto Ranging, Auto Power Off, Backlight and Work light
Technical
Parameters of Transmitter | |
Output Signal | 125kHz |
External Voltage | DC 12~400V AC 12~400V (50~60Hz)+-2.5% |
Fuse | F 0.5A 500V |
MIN Current | about 31mA |
MAX Current | about 115mA |
In Work | 0~40℃, with MAX relative humidity of 80% |
In Storage | -20~60℃, with MAX relative humidity of 80% |
Altitude | <2000m |
Technical
Parameters of Receiver | |
Depth of Tracking | the Depth of Tracking Depends on the Material and Specific
Applications |
Cable Locating Mode | Single pole application: about 0~2m |
Dual pole application | about 0~0.5m |
Single loop line | Up to 2.5m |
MIN Current | about 32mA |
MAX Current | about 89mA |
In Work | 0~40℃, with MAX relative humidity of 80% |
In Storage | -20~60℃, with MAX relative humidity of 80% |
Altitude | <2000m |
Depth of Tracking | the Depth of Tracking Depends on the Material and Specific
Applications |