- Stock: In Stock
- Model: Electricians Multimeter with Non-Contact voltage
Product overview:
Fluke 117 Electricians Multimeter with Non-Contact voltage
Fluke 117 Digital Multimeter for Electricians with
Non-Contact voltage
This Digital Multimeter includes integrated non-contact
voltage detection to help get the job done faster.
The Fluke 117 Digital Multimeter includes integrated
non-contact voltage detection and Auto Volts and LoZ functions that help
prevent false readings caused by ghost voltage. It is a compact True-RMS meter
for demanding applications like commercial buildings, hospitals, and schools
and helps get the job done faster.
Users around the world have said their 117 digital
multimeter is an investment in accuracy. The Fluke 117 provides Min/Max/Average
readings and measures frequency and capacitance. Plus, its easy-to-use
interface can save you time and enable you to move from job to job more
quickly.
The Fluke 110 Series has five true-rms digital multimeters,
each for specific users. The compact instruments offer convenient one-handed
operation and a backlit display with large, easy-to-read digits.
Specifications: Fluke 117 Electricians
Multimeter with Non-Contact voltage
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Safety | IEC 61010-1: Pollution Degree 2 | |
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy
Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) | |
AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or
shorts of | |
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A |
Accuracy | 1.5% + 3 | |
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 | |
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified
from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||