- Stock: In Stock
- Model: AC/DC Clamp Meter
Product overview:
Fluke 301D AC/DC Clamp Meter
The Fluke 301D Series AC/DC Clamp Meter is designed with a
lightweight and compact body, which allows you to carry it around in your
pocket. The slim and thin jaw can easily fit into tightly packed wires. The
Fluke 301D test current, voltage, resistance, continuity, frequency (voltage
and current), capacitance, and diode, etc.. You can handle multiple test needs
with just one tool. With the AC/DC function, it can be applied to more
application scenarios requiring DC testing, such as new energy of PV and wind
power, new energy vehicles, communications, data centers, etc..
Specifications: Fluke 301D AC/DC Clamp
Meter
AC Current (45 to 400 Hz) | Range | 60.00 A | 600.0 A |
Resolution | 0.01 A | 0.1 A | |
Accuracy | 2% + 10 | 2% + 5 | |
DC Current | Range | 60.00 A | 600.0 A |
Resolution | 0.01 A | 0.1 A | |
Accuracy | 2% + 10 | 2% + 5 | |
AC Voltage (45 to 400 Hz) | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1.5% + 5 | ||
DC Voltage | Range | 600.0 V | |
Resolution | 0.1 V | ||
Accuracy | 1% + 5 | ||
Resistance | Range | 600.0 Ω | |
Accuracy | 1% + 5 | ||
Voltage Frequency | Range | 9.999 Hz | |
Accuracy | 0.1% + 3 | ||
Current Frequency | Range | 45.0-400.0 Hz | |
Accuracy | 0.1% + 3 | ||
Capacitance | Range | 9.999 uF | 99.99 uF 999.9 uF |
Accuracy | 2% + 5 | 5% + 5 | |
Diode | Range | 3.000 V | |
Accuracy | 10% | ||
T-rms Value | - | ||
Continuity | ● | ||
Hold | ● | ||
Backlight | ● | ||
Safety rating | CAT III 300 V | ||
Weight | 154 g | ||
Size | 190 mm x 52 mm x 16 mm | ||
Jaw Opening | 34 mm | ||
Clamp Arm Size | 10 mm X 10 mm | ||
Battery | (2) AAA batteries | ||
General
Specifications
Maximum Voltage between any Terminal and Earth Ground | 300 V |
Maximum Differential Voltage between V/Ω and COM Terminals | 600 V |
Display (LCD) | 6000 counts, updates 3 times per second |
Battery Type | 2 AAA, IEC LR03 |
Battery Life | 500 hours minimum |
Auto Power Off Time | 20 minutes |
Temperature | Operating: -10 °C to 50 °C; |
Storage: -30 °C to 60 °C | |
Relative Humidity | Operating Humidity: Non condensing (<10°C); ≤ 90 % RH
at 10 °C to 30 °C; ≤ 75 % RH at 30 °C to 40 °C; ≤ 45 % RH at 40 °C to 50 °C; |
Altitude | Operating: 2000 m; Storage: 12000 m |
Temperature Coefficient | 0.1 x (specified accuracy) /°C (<18 °C or >28 °C) |
Dimensions (H x W x L) | 190 mm x 52 mm x 16 mm |
Weight | 132 g (301D/E 154 g) |
Jaw Opening | 34 mm |
Ingress Protection Rating | IP30 |
Safety | IEC 61010--1, IEC61010-2-032 CAT III 300 V, Pollution
Degree 2 |
Electromagnetic Environment | IEC 61326--1: Portable |