Product overview: Fluke 374 FC True-RMS AC/DC Clamp Meter

Fluke 374 FC delivers advanced troubleshooting performance and wireless connectivity

The Fluke 374 FC, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 A with the fixed jaw clamp or add an optional iFlex® flexible current probe to measure all the way to 2500 A. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 V and resistance to 6000 Ω.

Specifications: Fluke 374 FC True-RMS AC/DC Clamp Meter

General Specifications

AC Current via Jaw

Range

600.0 A

Resolution

0.1 A

Accuracy

2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)

Crest Factor (50 Hz/60 Hz)

2.5 @ 600 A
Add 2% for C.F. >2

AC Current via Flexible Current Probe

Range

2500 A

Resolution

0.1 A (≤ 600 A)
1 A (≤ 2500 A)

Accuracy

3% ±5 digits (5 – 500 Hz)

Crest Factor (50/60Hz)

2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2

Position Sensitivity

Flexible current probe

Distance from Optimum

 

i2500-10 Flex

i2500-18 Flex

Error

A

0.5 in (12.7 mm)

1.4 in (35.6 mm)

±0.5 %

B

0.8 in (20.3 mm)

2.0 in (50.8 mm)

±1.0 %

C

1.4 in (35.6 mm)

2.5 in (63.5 mm)

±2.0 %

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

DC Current

Range

600.0 A

Resolution

0.1 A

Accuracy

2% ±5 digits

AC Voltage

Range

1000 V

Resolution

0.1 V (≤600.0 V)
1 V (≤1000 V)

Accuracy

1.5% ±5 digits (20 Hz to 500 Hz)

DC Voltage

Range

1000 V

Resolution

0.1 V (≤600.0 V)
1 V (≤1000 V)

Accuracy

1% ±5 digits

mV dc

Range

500.0 mV

Resolution

0.1 mV

Accuracy

1% ±5 digits

Resistance

Range

6000 Ω

Resolution

0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)

Accuracy

1% ±5 digits

Capacitance

Range

1000 μF

Resolution

0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)

Accuracy

1% ±4 digits

Mechanical Specifications

Maximum voltage between any terminal and earth ground

1000 V

Batteries

2 AA, NEDA 15A, IEC LR6

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity -
non-condensing (< 10°C)

≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)

Operating altitude

3000 m

Storage altitude

12,000 m

Size (L x W x H)

249 x 85 x 45 mm

Weight

395 g

Jaw opening

34 mm

Flexible current probe diameter

7.5 mm

Flexible current probe cable length
(head to electronics connector)

1.8 m

Safety

IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V

IP rating

IEC 60529: IP30, non-operating

Radio Frequency Certification FCC ID

T68-FBLE IC:6627A-FBLE

Electromagnetic Compatibility (EMC)

International

IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.

Korea (KCC)

Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

USA (FCC)

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Temperature coefficients

Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C