Menu
Your Cart

Fluke 376FC

Fluke 376FC
Fluke 376FC
New
Fluke 376FC
Fluke 376FC
Fluke 376FC
  • Stock: In Stock
  • Model: True-RMS Clamp Meter with iFlex
RS0
Ex Tax: RS0

Product overview: Fluke 376 FC True-RMS Clamp Meter with iFlex

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.


Specifications: Fluke 376 FC True-RMS Clamp Meter with iFlex

General Specifications

AC Current via Jaw

Range

999.9 A

Resolution 

0.1 A

Accuracy 

2% ±5 digits (10 Hz to 100 Hz)

2.5% ±5 digits (100-500 Hz)

Crest Factor (50 Hz/60 Hz)

3 @ 500 A

2.5 @ 600 A

Add 2% for C.F. >2

AC Current via Flexible Current Probe

Range

2500 A

Resolution

0.1 A (≤ 600 A)

1 A (≤ 2500 A)

Accuracy

3% ±5 digits (5 – 500 Hz)

Crest Factor (50/60Hz)

3.0 at 1100 A

2.5 at 1400 A

1.42 at 2500 A

Add 2% for C.F. > 2

Position Sensitivity

 

i2500-10 Flex

i2500-18 Flex

A

 

 

Distance from Optimum

0.5 in (12.7 mm)

1.4 in (35.6 mm)

Error

±0.5 %

±0.5 %

B

 

 

Distance from Optimum

0.8 in (20.3 mm)

2.0 in (50.8 mm)

Error

±1.0 %

±1.0 %

C

 

 

Distance from Optimum

1.4 in (35.6 mm)

2.5 in (63.5 mm)

Error

±2.0 %

±2.0 %

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.

DC Current

Range

999.9 A

Resolution

0.1 A

Accuracy

2% ±5 digits

AC Voltage

Range

1000 V

Resolution

0.1 V (≤600.0 V)

1 V (≤1000 V)

Accuracy

1% ±5 digits (20 Hz to 500 Hz)

DC Voltage

Range

1000 V

Resolution

0.1 V (≤600.0 V)

1 V (≤1000 V)

Accuracy

1% ±5 digits

mV dc

Range

500.0 mV

Resolution

0.1 mV

Accuracy

1% ±5 digits

Frequency via Jaw

Range

5.0 Hz to 500.0 Hz

Resolution 

0.1 Hz

Accuracy 

0.5% ±5 digits

Trigger level 

5 Hz to 10 Hz, ≥10 A

10 Hz to 100 Hz, ≥5 A

100 Hz to 500 Hz, ≥10 A

Frequency via Flexible Current Probe

Range

5.0 Hz to 500.0 Hz

Resolution 

0.1 Hz

Accuracy 

0.5% ±5 digits

Trigger level 

5 Hz to 20 Hz, ≥25 A

20 Hz to 100 Hz, ≥20 A

100 Hz to 500 Hz, ≥25 A

Resistance

Range

60 kΩ

Resolution

0.1 Ω (≤600 Ω)

1 Ω (≤6000 Ω)

10 Ω (≤60 kΩ)

Accuracy

1% ±5 digits

Capacitance

Range

1000 μF

Resolution

0.1 μF (≤ 100 μF)

1 μ F (≤ 1000 μF)

Accuracy

1% ±4 digits

Mechanical Specifications

Maximum voltage between any terminal and earth ground

1000 V

Batteries

2 AA, NEDA 15A, IEC LR6

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Operating humidity -
non-condensing (< 10°C)

≤90% RH (at 10 °C to 30 °C)