- Stock: In Stock
- Model: Contact & Infrared Temperature Gun -40°C to 800°C
Product overview: 568
Contact & Infrared Temperature Gun
Looking for a temperature gun that can handle a wide
temperature range? Look no further than the Fluke 568 two-in-one infrared and
contact thermometer. This versatile thermometer offers more features than most
other infrared thermometers, all controlled through an intuitive graphical
display and menu.
With a 50:1 distance-to-spot ratio, you can measure smaller
objects from further away. And the rugged, ergonomic design is built to
withstand tough industrial, electrical, HVAC, and mechanical environments.
Specifications: 568
Contact & Infrared Temperature Gun
Product
Specifications | ||
Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) | |
Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); | |
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is
greater | ||
Display resolution | 0.1°C / 0.1°F | |
Infrared spectral response | 8 µm to 14 µm | |
Infrared response time | < 500 msec | |
Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) | |
Thermocouple Type-K input accuracy | -270°C to -40°C | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
-40°C to 1372°C | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is
greater | |
D:S (distance to measurement spot size) | 50:1 | |
Laser sighting | Single-point laser < 1 mw output Class 2 (II)
operation, 630 nm to 670 nm | |
Minimum spot size | 19 mm (0.75 in) | |
Emissivity adjustment | By built-in table of common materials or digitally
adjustable from 0.10 to 1.00 by 0.01 | |
Data storage with date/time stamp | 99 points | |
PC interface and cable | USB 2.0 with FlukeView® Forms software | |
Hi/Low alarms | Audible and two-color visual | |
Min/Max/Avg/Dif | Yes | |
Display | Dot matrix 98 x 96 pixels with function menus | |
Backlight | Two levels, normal and extra bright for darker
environments | |
Trigger lock | Yes | |
Switchable Celsius and Fahrenheit | Yes | |
Power | 2 AA/LR6 Batteries and USB when used with a PC | |
Battery life | If used continuously | Laser and backlight on,12 hours; laser and backlight off,
100 hours |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-40°F to 140°F) | |
Bead thermocouple Type-K range | -40°C to 260°C (-40°F to 500°F) | |
Bead thermocouple Type-K accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F),
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) | |