Product overview: Fluke 726 Precision Multifunction Calibrators

Process calibration designed specifically for process industries

The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.

Specifications: Fluke 726 Precision Multifunction Calibrators

Measurement Accuracy

Voltage DC

30.000 V

0.01% + 2 mV (upper display)

20.000 V

0.01% + 2 mV (lower display)

90.00 mV

0.01% + 10 μV

-10.00 mV to 75.00 mV

0.025% + 1 count (via TC connector)

Current DC

24.000 mA

0.01%+ 2 mA

Resistance

0.0 to 4000.0 Ω

± 0.015%

Frequency

2.0 to 1000.0 CPM

0.05% + 0.1 cpm

1.0 to 1000.0 Hz

0.05% + 0.1 Hz

1.00 to 15.00 kHz

0.05% + 0.01 kHz

Sensitivity

1 V peak-to-peak-minimum

Pressure

Accuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Source Accuracy

Voltage DC

100.00 mV

0.01% + 10 μV

20.000 V

0.01% + 2 mV

-10.00 mV to 75.00 mV

0.025% + 1 count (via TC connector)

Current DC

24.000 mA (Source)

0.01% + 2 μA

24.000 mA (Simulate)

0.01% + 2 μA

Resistance

Range, accuracy (percent of reading + floor) and excitation current

5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA

5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA

400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA

1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA

Frequency

2.0 to 1000.0 CPM

0.05%

1.0 to 1000.0 Hz

0.05%

1.0 to 10.0 kHz

0.25%

10.0 to 15.0 kHz

0.5%

Waveform

5 V p-p squarewave, -0.1 V offset

RTDs and Thermocouples

Measure and source accuracy

Cu10

1.8°C

NI-120

0.15°C

PT-100 (385)

0.45°C

PT-100 (392)

0.35°C

PT-100 (391-JIS)

0.35°C

PT-200 (385)

0.95°C

PT-500 (385)

0.55°C

PT-1000 (385)

0.35°C

RTD Resolution

0.01°C (0.01°F)

Cu10.01 C

0.1°C (0.1°F)

J

0.4°C

K

0.5°C

T

0.4°C

E

0.4°C

R

1.4°C

S

1.4°C

B

1.4°C

L

0.45°C

U

0.45°C

N

0.6°C

XK

0.4°C

BP

1.1°C

TC Resolution

J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F