Menu
Your Cart

Fluke 87V IMSK

Fluke 87V IMSK
New
Fluke 87V IMSK
  • Stock: In Stock
  • Model: IMSK Industrial Multimeter Service Combo Kit
RS0
Ex Tax: RS0

Product overview: Fluke 87V IMSK Industrial Multimeter Service Combo Kit

This combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, combined with the i400 AC current clamp. Together they provide the resolution and accuracy to efficiently troubleshoot any electrical system. The kit includes special accessories to make you even more productive on the job and will save over 15% compared with the individually priced items. Plus, you'll be working with the most trusted tools in the world.

Specifications: Fluke 87V IMSK Industrial Multimeter Service Combo Kit

Specifications

Voltage DC

Maximum voltage

1000 V

Accuracy

±(0.05% + 1)

Maximum resolution

10 µV

Voltage AC

Maximum voltage

1000 V

Accuracy

±(0.7% + 2) True RMS

AC bandwidth

20 kHz with low pass filter; 3 dB @ 1 kHz

Maximum resolution

0.1 mV

Current DC

Maximum amps

10 A (20 A for 30 seconds maximum)

Amps accuracy

±(0.2% + 2)

Maximum resolution

0.01 µA

Current AC

Maximum amps

10 A (20 A for 30 seconds maximum)

Amps accuracy

±(1.0% + 2) True RMS

Maximum resolution

0.1 µA

Resistance

Maximum resistance

50 MΩ

Accuracy

±(0.2% + 1)

Maximum resolution

0.1 Ω

Capacitance

Maximum capacitance

9,999 µF

accuracy

±(1% + 2)

Maximum resolution

0.01 nF

Frequency

Maximum frequency

200 kHz

Accuracy

±(0.005% + 1)

Maximum resolution

0.01 Hz

Duty cycle

Maximum duty cycle

99.9%

Accuracy

±(0.2% per kHz + 0.1%)

Maximum resolution

0.1%

Temperature measurement

–200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe

80 BK temperature probe

–40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater

Conductance

Maximum conductance

60.00 nS

Accuracy

±(1.0% + 10)

Maximum resolution

0.01 nS

Diode

Range

3 V

Resolution

1 mV

Accuracy

±(2% + 1)

Duty cycle range

Accuracy

Within ±(0.2% per kHz + 0.1%)

Environmental Specifications

Operating temperature

–20 °C to + 55 °C

Storage temperature

–40 °C to + 60 °C

Humidity (without condensation)

0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)

Operating Altitude

2000 m

Safety Specifications

Overvoltage category

EN 61010–1 to 1000 V CAT III, 600V CAT IV

Agency approvals

CE, CSA, RCM

Mechanical and General Specifications

Size

201 x 98 x 52 mm (with holster)

Weight

355 g
624 g – with holster

Display

Digital

6000 counts updates 4/sec.
19,999 counts in high–resolution mode

Analog

32 segments, updates 40/sec

Frequency

19,999 counts, updates 3/sec at > 10 Hz

Battery Life

Alkaline

~400 hours typical, without backlight

Shock

1 Meter drop per IEC 61010–1:2001

Vibration

Per MIL–PRF–28800 for a Class 2 instrument

Specifications: Fluke i400 AC Current Clamp

Specifications

Nominal current range

400 A

Continuous current range

1 A - 400 A

Maximum non-destructive current

1000 A

Lowest measurable current

1 A

Basic accuracy

2% + 0.06 A

(45-400 Hz)

(% reading + floorspec)

Useable frequency

5 Hz - 20 kHz

Output level(s)

1 mA/A

Safety Specifications

Safety

CAT IV 600 V, CAT III, 1000 V

Maximum voltage

1000 V AC rms from earth to ground, in compliance with EN61010

Mechanical and General Specifications

Maximum conductor diameter

32 mm (1.25 in)

Maximum conductor size (busbar)

750 MCM

Output cable length

1.5 m (59 in)

Shrouded banana plugs