- Stock: In Stock
- Model: IMSK Industrial Multimeter Service Combo Kit
Product overview:
Fluke 87V IMSK Industrial Multimeter Service Combo Kit
This combo kit is built around the Fluke 87V, the most
widely used industrial digital multimeter in the world, combined with the i400
AC current clamp. Together they provide the resolution and accuracy to
efficiently troubleshoot any electrical system. The kit includes special
accessories to make you even more productive on the job and will save over 15%
compared with the individually priced items. Plus, you'll be working with the
most trusted tools in the world.
Specifications: Fluke
87V IMSK Industrial Multimeter Service Combo Kit
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 10 µV | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.01 µA | |
Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) True RMS | |
Maximum resolution | 0.1 µA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Maximum frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement | –200.0 °C – 1090 °C | |
80 BK temperature probe | –40.0 °C – 260 °C | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | ||
Operating temperature | –20 °C to + 55 °C | |
Storage temperature | –40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) | |
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
Agency approvals | CE, CSA, RCM | |
Mechanical and
General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g | |
Display | Digital | 6000 counts updates 4/sec. |
Analog | 32 segments, updates 40/sec | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 | |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument | |
Specifications: Fluke
i400 AC Current Clamp
Specifications | |
Nominal current range | 400 A |
Continuous current range | 1 A - 400 A |
Maximum non-destructive current | 1000 A |
Lowest measurable current | 1 A |
Basic accuracy | 2% + 0.06 A |
(45-400 Hz) | |
(% reading + floorspec) | |
Useable frequency | 5 Hz - 20 kHz |
Output level(s) | 1 mA/A |
Safety
Specifications | |
Safety | CAT IV 600 V, CAT III, 1000 V |
Maximum voltage | 1000 V AC rms from earth to ground, in compliance with
EN61010 |
Mechanical and
General Specifications | |
Maximum conductor diameter | 32 mm (1.25 in) |
Maximum conductor size (busbar) | 750 MCM |
Output cable length | 1.5 m (59 in) |
Shrouded banana plugs | Yes |